PPGENE PÓS-GRADUAÇÃO EM ENERGIA FUNDAÇÃO UNIVERSIDADE FEDERAL DO ABC Telefone/Ramal: Não informado http://propg.ufabc.edu.br/ppgene

Banca de QUALIFICAÇÃO: JOSÉ CARLOS DA COSTA FILHO

Uma banca de QUALIFICAÇÃO de MESTRADO foi cadastrada pelo programa.
STUDENT : JOSÉ CARLOS DA COSTA FILHO
DATE: 05/04/2024
TIME: 14:30
LOCAL: Online
TITLE:

Surrogate-based optimization of parabolic trough collectors with variable geometry operating with nanofluids


PAGES: 56
BIG AREA: Engenharias
AREA: Engenharia Mecânica
SUBÁREA: Fenômenos de Transporte
SPECIALTY: Transferência de Calor
SUMMARY:

Solar energy has emerged as a leading player in current scenarios promoting the decarbonization of energy matrices. Among the methods of harnessing this energy potential, concentrating collectors stand out as the most well-established technology, with the parabolic trough collector (PTC) dominating the market. Among the research efforts aimed at enhancing the heat transfer of PTCs, the dispersion of nanoparticles in heat transfer fluids (HTF) has shown improvements of up to 27% in collector thermal performance as reported in the literature. However, as a side effect, the nanoparticles result in an increase in the system's pumping power. In this work, through surrogate modeling, multi-objective optimizations were conducted using the NSGA-II algorithm aiming to maximize thermal efficiency and minimize pumping power in an arrangement of 8 collectors with variable geometry (including lengths, mirror widths, absorber tube diameters, and glass cover diameters) operating with two nanofluids, Al2O3-Syltherm 800 and Cu-Syltherm 800, at volumetric fractions between 0.1 and 5% under different irradiance conditions (500 - 1000 W/m2), inlet temperatures (400 -- 500 K), and volumetric flow rates (0.005 -- 0.01 m3/s). Preliminary results indicated that volumetric fractions less than 0.5% allow for a reduction in pumping power of up to 3% compared to the reference collector ET-150. From the selection of geometries indicated on the Pareto frontiers, there was an increase of 1.8% in thermal efficiency for the arrangement operating under the condition of 500 W/m2 irradiance, 500 K inlet temperature, and 0.005 m3/s volumetric flow rate, while the resulting pumping power was reduced by 14.9%. Furthermore, an increase in exergy efficiency of 1.74%, and a decrease in the exergy destruction rate of 0.15%, were observed.


COMMITTEE MEMBERS:
Presidente - Interno ao Programa - 2312727 - DANIEL JONAS DEZAN
Membro Titular - Examinador(a) Interno ao Programa - 1985515 - ANTONIO GARRIDO GALLEGO
Membro Titular - Examinador(a) Externo à Instituição - GHERHARDT RIBATSKI - USP
Membro Suplente - Examinador(a) Interno ao Programa - 1600874 - MARCELO MODESTO DA SILVA
Notícia cadastrada em: 18/03/2024 09:22
SIGAA | UFABC - Núcleo de Tecnologia da Informação - ||||| | Copyright © 2006-2024 - UFRN - sigaa-2.ufabc.int.br.sigaa-2-prod