PPGEEL PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA FUNDAÇÃO UNIVERSIDADE FEDERAL DO ABC Phone: Not available http://propg.ufabc.edu.br/ppgeel

Banca de DEFESA: OSCAR GUILLERMO PATIÑO GONZALEZ

Uma banca de DEFESA de MESTRADO foi cadastrada pelo programa.
STUDENT : OSCAR GUILLERMO PATIÑO GONZALEZ
DATE: 16/10/2023
TIME: 14:00
LOCAL: https://meet.google.com/opw-fhvz-jfj
TITLE:

Method to mode distance protection of wind power plants in stability analysis


PAGES: 60
BIG AREA: Engenharias
AREA: Engenharia Elétrica
SUBÁREA: Sistemas Elétricos de Potência
SPECIALTY: Transmissão da Energia Elétrica, Distribuição da Energia Elétrica
SUMMARY:

Transient analysis programs usually have a simplified representation of protection relays, in addition, these programs usually only represent single-phase disturbances in the system. In this work, a co-simulation scheme is proposed, associating a transient stability analysis program with a short-circuit calculation program to improve the representation of protection relays in the transient stability analysis. With a co-simulation scheme, it will be possible during the simulation of electromechanical transients to check at each step, the state of protection for a given disturbance, using the results of the parallel simulation of the disturbance in the short-circuit program. The proposal is validated using commercial electromechanical stability software and a user-implemented short-circuit program. The advantage of this scheme is the use of protection settings made in short-circuit programs, which have detailed relay models provided by manufacturers, in stability analysis simulations. This scheme is applied to evaluate the performance of the distance protection in case of faults involving wind generation. Wind generators have a different response to faults than traditional synchronous generators and, due to this difference, several techniques have been proposed for distance protection of lines connected to wind power plants. For this, a power system with a high proportion of wind generation is modeled in CEPEL's ANATEM software and a short-circuit program is implemented in MATLAB for the co-simulation scheme. The method is validated by employing different protection techniques with the traditional method of transmission line distance protection.


COMMITTEE MEMBERS:
Presidente - Interno ao Programa - 1669195 - AHDA PIONKOSKI GRILO PAVANI
Membro Titular - Examinador(a) Interno ao Programa - 1545354 - RICARDO CANELOI DOS SANTOS
Membro Titular - Examinador(a) Externo ao Programa - 3291731 - VICTORIA ALEJANDRA SALAZAR HERRERA
Membro Suplente - Examinador(a) Interno ao Programa - 1671333 - EDMARCIO ANTONIO BELATI
Membro Suplente - Examinador(a) Externo ao Programa - 433669 - FABIANA APARECIDA DE TOLEDO SILVA
Notícia cadastrada em: 26/09/2023 14:09
SIGAA | UFABC - Núcleo de Tecnologia da Informação - ||||| | Copyright © 2006-2024 - UFRN - sigaa-2.ufabc.int.br.sigaa-2-prod